Analysis snapshotSnapshot decision:BUY

Thermo Scientific Microm HM 325-2 — Auction Analysis

This repairable Microm HM 325-2 is physically identified as catalog 902100 with visually present specimen-clamp and blade-carrier hardware, but no mechanical or sectioning test is evidenced. The $25 observed bid remains below a $500 blind ceiling that preserves room for repair and precision-feed risk.

Analysis snapshot · Historical — observed August 31, 2026. The scheduled close date of September 2, 2026 has passed. The price, evidence, economics, and recommendation remain exactly as recorded and are not current.

Decision at a glance

RecommendationBUY
Maximum hammer bid
$500

The auction bid ceiling supported by this analysis, if one is defensible; see costs below for buyer-premium treatment.

Why this decision

BUY below $500 only for an eligible buyer who accepts repairable precision-mechanical risk; a sectioning or feed test should control any bid increase.

See costs and maximum bid for the displayed assumptions and buyer-premium treatment.

Snapshot observed bid
$25
Bidders
1
Blind-model resale
$2,500
Snapshot provenance and timing · observed August 31, 2026 · scheduled close September 2, 2026

GSA Auctions sale 3-1-QSC-I-26-559, lot 006 · Muskogee, Oklahoma
Snapshot observed August 31, 2026
Scheduled close September 2, 2026
Analysis prepared August 31, 2026
Published August 31, 2026 · page updated August 31, 2026

Prepared and published by Oleksii Udod for LotCaliper.

View official GSA lot

Continue after this auction

This auction snapshot is historical. Continue with related research, or review a relevant published analysis whose recorded scheduled close has not passed.

These are individually prepared, time-stamped analyses with recorded scheduled closes. Verify the official auction before acting.

Auction snapshot

At the August 31, 2026 observation, the high bid was $25 with one bidder. This immutable observation is not a final auction result.

A repairable microtome can look configured and complete while still having economically decisive precision-feed and sectioning risk.

Review and correction history

Independent review not recorded for this legacy analysis. No corrections recorded.

View review and correction details

Independent review not recorded

Published before the current independent-review gate; no completed independent review is recorded.

How independent review works
How evidence is classified

Seller facts, photo-derived observations, manufacturer context, unknowns, and LotCaliper assumptions remain explicitly separated.

Source Confirmed

Seller-confirmed

  • One Thermo Scientific / Microm HM 325-2, catalog 902100; seller condition is repairable.
  • The observation records a $25 high bid with one bidder.

Photo Derived

Photo-derived

  • Clamp/orienting and blade-carrier hardware appear installed.
  • A label reading Inspection Due 06-26 is historical maintenance context, not a passed inspection.

Not Established

Not established

  • Exact blade-carrier and clamp part numbers, factory 902100A/902100ER package identity, complete accessories, and all mechanical/sectioning performance.
  • A current maintenance inspection, repair diagnosis, or final auction result.

Manufacturer Context

Independent context

  • Epredia distinguishes base 902100 from configured 902100A and 902100ER packages; new and dealer pricing are not used resale comps.

Lotcaliper Assumption

LotCaliper assumptions

  • $2,500 conservative post-verification resale.
  • $500 blind maximum hammer after logistics, testing, missing-accessory, selling, profit, and uncertainty reserves.

Equipment identity

Laboratory · quantity 1

Thermo Scientific / Microm HM 325-2 rotary microtome, catalog 902100

Identity confidence: High

Identity evidence
  • Physical label and seller description identify Microm HM 325-2, serial 59906, catalog 902100; serial is retained only because the approved specification explicitly requires it.

    GSA Auctions · Image · observed August 31, 2026

Configuration

Visually present E-style disposable blade-carrier hardware

Possible · Medium confidence

Configuration evidence
  • Visible lower cutting assembly appears consistent with an E-style blade carrier, but no part number is readable.

    GSA Auctions · Image · observed August 31, 2026

Visually present cassette-style specimen clamp / orienting assembly

Possible · Medium confidence

Configuration evidence
  • Visible upper specimen assembly appears consistent with a cassette-style quick-release clamp, but no part number is readable.

    GSA Auctions · Image · observed August 31, 2026

Factory package 902100A or 902100ER and complete standard accessories

Not established · no source evidence establishes presence or absence

Configuration evidence
  • Base catalog 902100 does not establish a 902100A or 902100ER package; waste tray, tools, cover, and documentation are not established.

    GSA Auctions · Image · observed August 31, 2026

Condition

As-is / repair risk

Seller classifies the microtome as repairable; no handwheel, feed, retraction, clamp, blade alignment, or actual sectioning performance is evidenced.

Evidence confidence: High

Condition evidence
  • Seller repairable condition and supplied images provide no precision-mechanical functional test.

    GSA Auctions · Text · observed August 31, 2026

Market evidence

Market evidence strength

Medium

Public auditability

Limited Legacy

Evidence recency

Not Recorded

No structured comparable-evidence metadata was preserved for this dated snapshot. Public auditability is limited; the numeric resale snapshot cannot be independently audited from comparable records on this page.

Legacy evidence counts were not preserved. Unknown is not reported as zero.

Sensitivity and robustness

Survives

The published decision survives the selected downside check under the stated bounded assumptions.

Blind/as-is model

Max hammer
$500
Gross resale model
$1,500–$2,500

The $500 blind ceiling reserves for repair, accessories, precision verification, selling friction, and uncertainty; the preserved $25 observation is not a final price.

Costs and maximum bid

Transaction / operating costAmountBasis
Selling Fees$375LotCaliper assumption: 15% of conservative gross resale.
Shipping$250LotCaliper pickup, protective packing, and inbound-shipping reserve; not a carrier quote.
Testing Repair Reserve$300LotCaliper cleaning, mechanical verification, and modest refurbishment reserve.
Other$150LotCaliper reserve for unresolved accessories and configuration hardware.
Risk Buffer$300Precision feed, repairable-condition, and unverified sectioning reserve.
Buyer premium
Not modeled
Return requirements
$625 minimum profit · 30% minimum ROI
Computed bid constraints

Profit floor: $500

ROI floor: $635

Binding: Profit floor

Snapshot blind/as-is max hammer
$500
Modeled result at recorded bid
$625 profit · 75.00% modeled ROI

This is a reseller ceiling, not a prediction of the auction's closing price. Any buyer premium or other unquoted acquisition charge must be deducted before bidding.

Configuration evidence and repairable microtome economics

The base 902100 label and visibly installed hardware can coexist. The asset is published as a configured HM 325-2, not as an unsupported factory package.

The seller's repairable classification controls over exterior appearance. A handwheel movement check alone is not an adequate substitute for feed and sectioning verification.

  • Verify the exact blade carrier and specimen clamp, inclusion, feed/retraction, brake, backlash, alignment, and repeatable sectioning before raising the ceiling.
  • Do not use new-package, dealer-refurbished, or marketplace asking prices as completed-sale evidence.

Recommendation and rationale

Snapshot decision

BUY

BUY below $500 only for an eligible buyer who accepts repairable precision-mechanical risk; a sectioning or feed test should control any bid increase.

Confidence

Identity
High
Configuration
Medium
Condition
Low
Market Support
Medium
Costs
Medium

Market support assesses how well the available evidence supports the resale assumption. Exact third-party marketplace records may be omitted when source-use rights are unclear. Each dimension uses the published methodology rubric; a confidence label measures the strength and boundedness of its evidence, not the likelihood of a profitable outcome.

Risks and unknowns

High · Precision Mechanics Unverified

No evidence establishes smooth feed, backlash, retraction, clamp retention, blade alignment, or repeatable sectioning.

A configured exterior does not prove micron-scale mechanical performance.

High · Factory Package Unresolved

Catalog 902100 is not silently promoted to a 902100A or 902100ER package.

The visible clamp and blade-carrier hardware lack readable part numbers.

Medium · Maintenance Status Unverified

The visible Inspection Due 06-26 label is historical maintenance context only.

It does not prove that an overdue June 2026 inspection occurred or passed.

Sources

View cited public sources