- Four PF 6040 TcpO₂/pCO₂ modules are photo-confirmed; two connected electrode assemblies are visible.
Four photo-confirmed PF 6040 TcpO₂/pCO₂ modules make this a valuable PeriFlux 6000 configuration, but only two electrode assemblies are visibly established and no function, recognition, calibration, or measurement evidence supports more than a ~$700 blind ceiling.
The auction bid ceiling supported by this analysis, if one is defensible; see costs below for buyer-premium treatment.
Why this decision
REVIEW: the ~$700 blind ceiling uses a $4,000 post-verification resale model, while observed auction price, module recognition, electrode health, and measurement performance remain unresolved.
See costs and maximum bid for the displayed assumptions and buyer-premium treatment.
GSA Auctions sale 1-1-QSC-I-26-310, lot 003 · Augusta, Maine 04330
Snapshot observed September 2, 2026
Scheduled close September 8, 2026
Analysis prepared September 2, 2026
Published September 2, 2026 · page updated September 2, 2026
Prepared and published by Oleksii Udod for LotCaliper.
View official GSA lotThis auction snapshot is historical. Continue with related research, or review a relevant published analysis whose recorded scheduled close has not passed.
These are individually prepared, time-stamped analyses with recorded scheduled closes. Verify the official auction before acting.
Auction snapshot
This page preserves the September 2, 2026 GSA preview observation for sale 1-1-QSC-I-26-310, lot 003. No high bid or bidder count was displayed.
Four installed measurement modules do not create a complete four-channel clinical system without healthy, recognized electrodes and demonstrated measurements.
Independent review not recorded for this legacy analysis. No corrections recorded.
Independent review not recorded
Published before the current independent-review gate; no completed independent review is recorded.
How independent review worksSeller facts, photo-derived observations, manufacturer context, unknowns, and LotCaliper assumptions remain explicitly separated.
Source Confirmed
Photo Derived
Not Established
Manufacturer Context
Lotcaliper Assumption
Analyzer · quantity 1
Identity confidence: High
Four installed PF 6040 tcpO₂/pCO₂ modules are visible in the supplied rear-module photograph.
GSA Auctions · Image · observed September 2, 2026
Not established · no source evidence establishes presence or absence
Only two connected electrode assemblies are visibly established; empty blue and purple module connectors do not prove four usable electrodes.
GSA Auctions · Image · observed September 2, 2026
Not established · no source evidence establishes presence or absence
No PF 6050 pressure module is visible.
GSA Auctions · Image · observed September 2, 2026
Untested
Evidence confidence: High
The touchscreen is dark and the supplied photographs are not functional evidence.
GSA Auctions · Image · observed September 2, 2026
Market evidence strength
Medium
Public auditability
Limited Legacy
Evidence recency
Not Recorded
No structured comparable-evidence metadata was preserved for this dated snapshot. Public auditability is limited; the numeric resale snapshot cannot be independently audited from comparable records on this page.
Legacy evidence counts were not preserved. Unknown is not reported as zero.
Requires Verification
The scenarios show potentially workable economics, but the stated verification gate must be resolved before bidding responsibly.
The ceiling reserves for logistics, functional/calibration work, aged or missing electrodes, selling friction, and uncertainty.
| Transaction / operating cost | Amount | Basis |
|---|---|---|
| Selling Fees | $600 | LotCaliper assumption: 15% of modeled gross resale. |
| Shipping | $300 | LotCaliper pickup, packing, rigging, and inbound-logistics reserve; not a carrier or GSA quote. |
| Testing Repair Reserve | $400 | LotCaliper functional-test and diagnostic reserve. |
| Risk Buffer | $500 | Module, touchscreen/software, electrode, and hidden-condition risk reserve. |
| Other | $700 | LotCaliper missing-component, configuration, or recovery reserve; not a seller or service quote. |
Profit floor: $1,000
ROI floor: $715
Binding: ROI floor
This is a reseller ceiling, not a prediction of the auction's closing price. Any buyer premium or other unquoted acquisition charge must be deducted before bidding.
The four PF 6040 modules are positive configuration evidence, but only two electrode assemblies are established. The analysis does not call this a Combined pressure/TcpO₂ system because no PF 6050 pressure module is visible.
A stronger value requires booting, recognition of all modules, qualifying sufficient electrodes, and demonstrating stable measurement and reporting workflow.
Snapshot decision
REVIEWREVIEW: the ~$700 blind ceiling uses a $4,000 post-verification resale model, while observed auction price, module recognition, electrode health, and measurement performance remain unresolved.
Market support assesses how well the available evidence supports the resale assumption. Exact third-party marketplace records may be omitted when source-use rights are unclear. Each dimension uses the published methodology rubric; a confidence label measures the strength and boundedness of its evidence, not the likelihood of a profitable outcome.
High · Electrode Count Unresolved
Only two electrode assemblies are photo-confirmed.
High · Pressure Module Not Evidenced
No PF 6050 pressure module is visible.
Official auction provenance for the immutable preview observation.
Official platform and workflow context; linked and paraphrased.