- Fluke 754; repairable seller condition.
- Detailed bid history reached a $1,890 closing high bid with eight visible bidder identities.
The Fluke 754 is a current high-value HART process calibrator, but this repairable unit was not shown powered on, its BP7240 battery is confirmed missing, and the normal charger, cables, leads, clips, and calibration paperwork are not evidenced. Exact-model resale support does not leave enough spread at the $1,890 closing high bid; the blind/as-is ceiling is about $900.
The auction bid ceiling supported by this analysis, if one is defensible; see costs below for buyer-premium treatment.
Why this decision
SKIP: the $1,890 closing high bid exceeds the roughly $900 blind hammer ceiling after battery, accessory, repair, verification, selling-cost, and return-risk reserves.
See costs and maximum bid for the displayed assumptions and buyer-premium treatment.
GSA Auctions sale 2-1-QSC-I-26-323, lot 004 · Frankfort, Kentucky
Snapshot observed August 27, 2026
Scheduled close August 7, 2026
Analysis prepared August 27, 2026
Published August 27, 2026 · page updated August 27, 2026
Prepared and published by Oleksii Udod for LotCaliper.
This auction snapshot is historical. Continue with related research, or review a relevant published analysis whose recorded scheduled close has not passed.
These are individually prepared, time-stamped analyses with recorded scheduled closes. Verify the official auction before acting.
Auction snapshot
Detailed bid history reached a $1,890 closing high bid with eight visible bidders. That detailed value takes precedence over the stale summary and is not presented as an awarded or settled transaction.
A current professional calibrator is not automatically a reseller bargain below $2,000 when portable power, normal kit accessories, repair status, and calibration remain unresolved.
Independent review not recorded for this legacy analysis. No corrections recorded.
Independent review not recorded
Published before the current independent-review gate; no completed independent review is recorded.
How independent review worksSeller facts, photo-derived observations, manufacturer context, unknowns, and LotCaliper assumptions remain explicitly separated.
Source Confirmed
Photo Derived
Not Established
Manufacturer Context
Lotcaliper Assumption
Calibration · quantity 1
Identity confidence: High
Seller and photographs establish one Fluke 754; GSA preview item 372659.
GSA Auctions · Image · observed August 27, 2026
Confirmed missing · High confidence
The battery bay is visibly empty; the BP7240 battery is confirmed missing.
GSA Auctions · Image · observed August 27, 2026
Confirmed · High confidence
A heavily worn and stained OEM soft case is visible.
GSA Auctions · Image · observed August 27, 2026
Not established · no source evidence establishes presence or absence
The supplied evidence does not establish the normal kit accessories or calibration paperwork.
GSA Auctions · Image · observed August 27, 2026
Not established · no source evidence establishes presence or absence
Pressure measurement requires a compatible external module; none is established in the lot.
GSA Auctions · Image · observed August 27, 2026
As-is / repair risk
Evidence confidence: High
Seller condition statement, paraphrased.
GSA Auctions · Text · observed August 27, 2026
Untested
Evidence confidence: High
Photo-derived absence of portable power and no operating evidence.
GSA Auctions · Image · observed August 27, 2026
Market evidence strength
Medium High
Public auditability
Limited Legacy
Evidence recency
Not Recorded
No structured comparable-evidence metadata was preserved for this dated snapshot. Public auditability is limited; the numeric resale snapshot cannot be independently audited from comparable records on this page.
Legacy evidence counts were not preserved. Unknown is not reported as zero.
Fails
The modeled economics fail the standard reseller requirements under the stated assumptions.
At the $900 ceiling, modeled profit is about $800 and ROI about 30.8%. At the preserved $1,890 closing high bid, modeled profit is about negative $190 and ROI about negative 5%.
| Transaction / operating cost | Amount | Basis |
|---|---|---|
| Selling Fees | $600 | LotCaliper assumption: 15% of modeled gross resale. |
| Shipping | $100 | LotCaliper pickup, packing, rigging, and inbound-logistics reserve; not a carrier or GSA quote. |
| Testing Repair Reserve | $650 | LotCaliper functional-test and diagnostic reserve. |
| Risk Buffer | $950 | Missing battery, charger, leads and communications accessories plus repair and return risk. |
Profit floor: $1,200
ROI floor: $915
Binding: ROI floor
This is a reseller ceiling, not a prediction of the auction's closing price. Any buyer premium or other unquoted acquisition charge must be deducted before bidding.
The dark display is neither failure evidence nor positive operating evidence because the battery is absent. Meaningful diligence requires a known-good power source, completed self-tests, source/measure checks, loop-power and HART verification, and calibration against traceable standards.
Snapshot decision
SKIPSKIP: the $1,890 closing high bid exceeds the roughly $900 blind hammer ceiling after battery, accessory, repair, verification, selling-cost, and return-risk reserves.
Market support assesses how well the available evidence supports the resale assumption. Exact third-party marketplace records may be omitted when source-use rights are unclear. Each dimension uses the published methodology rubric; a confidence label measures the strength and boundedness of its evidence, not the likelihood of a profitable outcome.
High · Functionality Unverified
Battery absent and no operating evidence.
High · Battery Missing
Direct photo evidence.
High · Accessories Incomplete
Auction evidence is closer to a bare calibrator plus worn case than a complete kit.
High · Calibration Unverified
No certificate or functional verification is established.
High · Repairable Condition
Seller condition statement.
Official public provenance for auction facts; no unverified direct item URL is invented.
Official model, HART, function, and normal-kit context; linked and paraphrased.
Official battery context; linked and paraphrased.