- Two BioFire Diagnostics FilmArray 2.0 instrument chassis are established.
- Both housings, lids, pouch chambers, rear fans, Ethernet ports, and power inlets are visible.
Two BioFire FilmArray 2.0 instrument chassis are confirmed, but no control computer/software, peripherals, run evidence, readable serials, recall clearance, decontamination history, or service record is established. The bare-pair blind model supports a $0 hammer and remains REVIEW because no bid was captured.
The auction bid ceiling supported by this analysis, if one is defensible; see costs below for buyer-premium treatment.
Why this decision
REVIEW: no high bid was captured, but the $1,100 bare-pair conservative resale leaves only the standard $500 profit at a zero hammer after stated reserves.
See costs and maximum bid for the displayed assumptions and buyer-premium treatment.
GSA Auctions sale 1-1-QSC-I-26-293, lot 059 · Oscar G. Johnson VA Medical Center, Iron Mountain, Michigan
Snapshot observed September 13, 2026
Scheduled close September 16, 2026
Analysis prepared September 13, 2026
Published September 13, 2026 · page updated September 13, 2026
Prepared and published by Oleksii Udod for LotCaliper.
View official GSA lotThis auction snapshot is historical. Continue with related research, or review a relevant published analysis whose recorded scheduled close has not passed.
These are individually prepared, time-stamped analyses with recorded scheduled closes. Verify the official auction before acting.
Auction snapshot
This page preserves the September 13, 2026 GSA observation for sale 1-1-QSC-I-26-293, lot 059. No high bid or bidder count was displayed; blank fields are not a $0 result or final no-bid outcome.
Two complete-looking molecular instruments can still be non-turnkey when their system computer, software, serial-specific recall clearance, decontamination history, and completed runs are unknown.
Independent review not recorded for this legacy analysis. No corrections recorded.
Independent review not recorded
Published before the current independent-review gate; no completed independent review is recorded.
How independent review worksSeller facts, photo-derived observations, manufacturer context, unknowns, and LotCaliper assumptions remain explicitly separated.
Source Confirmed
Photo Derived
Not Established
Manufacturer Context
Lotcaliper Assumption
Laboratory · quantity 2
Identity confidence: High
Seller description and supplied photographs identify two BioFire Diagnostics FilmArray 2.0 units.
GSA Auctions · Image · observed September 13, 2026
Not established · no source evidence establishes presence or absence
The supplied photographs establish instrument chassis only; no computer/software system or normal peripherals are shown.
GSA Auctions · Image · observed September 13, 2026
Not established · no source evidence establishes presence or absence
No complete matching workflow/accessory set, decontamination record, recall correction record, or service documentation is evidenced.
GSA Auctions · Image · observed September 13, 2026
Not established · no source evidence establishes presence or absence
Rear labels are too blurred to determine exact catalog designation or whether either serial appears in FDA recall Z-3122-2024.
GSA Auctions · Image · observed September 13, 2026
Untested
Evidence confidence: High
Intact housings and pouch chambers are not proof of a successful diagnostic run.
GSA Auctions · Image · observed September 13, 2026
Market evidence strength
Medium Low
Public auditability
Limited Legacy
Evidence recency
Not Recorded
No structured comparable-evidence metadata was preserved for this dated snapshot. Public auditability is limited; the numeric resale snapshot cannot be independently audited from comparable records on this page.
Legacy evidence counts were not preserved. Unknown is not reported as zero.
Requires Verification
The scenarios show potentially workable economics, but the stated verification gate must be resolved before bidding responsibly.
The $0 ceiling credits two chassis only and does not assume control computer/software, recall clearance, service, warranty, or successful pouch runs.
| Transaction / operating cost | Amount | Basis |
|---|---|---|
| Selling Fees | $165 | LotCaliper assumption: 15% of modeled gross resale. |
| Shipping | $150 | LotCaliper pickup, packing, rigging, and inbound-logistics reserve; not a carrier or GSA quote. |
| Testing Repair Reserve | $150 | LotCaliper functional-test and diagnostic reserve. |
| Risk Buffer | $135 | No computer/software, recall, decontamination, platform-obsolescence, function, and specialist-liquidity risk reserve. |
Profit floor: $0
ROI floor: $284
Binding: Profit floor
This is a reseller ceiling, not a prediction of the auction's closing price. Any buyer premium or other unquoted acquisition charge must be deducted before bidding.
The missing control environment is not a minor accessory issue: one compatible BioFire computer can control both instruments, but the chassis alone do not establish a usable system for a buyer without that environment.
FDA recall Z-3122-2024 is open and serial-specific. It does not mean both units are recalled, but the unreadable labels mean no recall-clearance credit can be used.
Snapshot decision
REVIEWREVIEW: no high bid was captured, but the $1,100 bare-pair conservative resale leaves only the standard $500 profit at a zero hammer after stated reserves.
Market support assesses how well the available evidence supports the resale assumption. Exact third-party marketplace records may be omitted when source-use rights are unclear. Each dimension uses the published methodology rubric; a confidence label measures the strength and boundedness of its evidence, not the likelihood of a profitable outcome.
High · Serial Specific Recall Unresolved
A recall is serial-specific and must not be generalized to every FilmArray 2.0 unit.
High · Control Workflow Not Established
The instruments are designed to operate in a BioFire software-controlled system.
Official auction provenance for the immutable preview observation.
Official system architecture, computer/software, diagnostics, and decontamination context; linked and paraphrased.
Official serial-specific open-recall context; linked and paraphrased.